64 Analog Inputs
|
32 Analog inputs for high accuracy recording of temperature sensor signals
|
|
Compatible with : |
|
PT1000 |
|
KTY81 |
|
NTC |
| 12 Analog inputs for 0-10Volts Analog sensors |
|
Suitable for : |
|
Room temperature sensors |
|
Fluid pressure sensors |
|
Fuel level sensor |
| 4 Analog inputs 4-20Ma Sensors |
|
Suitable for : |
|
Room temperature sensors |
|
Fluid pressure sensors |
|
Fuel level sensor |
| 8 pairs (16 singles) of 0-5Volts analog input device with single plug ability |
|
Suitable for : Flow meter and integrated temperature sensor |
12 Digital Inputs
|
| 8 High speed digital inputs for flow meter connections |
|
Suitable for : |
|
Turbine Flow meter Type |
|
External device with Gnd reference signals |
| 4 Digital input 5 to 24VDc |
|
Suitable for : |
|
Switches |
|
External relays |
|
PLC |
16 Analog Outputs
|
| 16 Analog outputs 0-10Volts and/or PWM* |
|
Suitable for : Water flow pumps from various Brand |
|
|
|
*PWM Characteristics |
|
Analog and PWM signal can be mixed over the 16 channels |
|
Programmable PWM frequency between 0.1 and 5KHz |
|
PWM resolution ratio : 8Bits (256 levels) for accurate regulation |
|
PWM signal level adjustable from 1 to 10Volts |
16 Digital Outputs
|
| 8 on board relays 2A for potential free connection |
|
Suitable for : |
|
Heating devices |
|
Heating pump |
|
Pellets Oven |
|
Air conditioning |
|
Fresh air exchanger |
| 8 auxiliary output for external relay connection |
| 4 digital optocoupled 24 volts output signals |
|
Suitable for : |
|
Warning lamps |
|
Light tower |
|
PLC |
|
Auxiliary devices |
| 20 High Voltage 230Volts single phase Output 1A |
|
Suitable for : |
|
Regular water pump |
|
Aeration Fans |
|
Water mixing valves |
|
Water area valves |
Communication
|
| 1 Ethernet adaptor |
| 1 Wifi adaptor |
|
| 1 internal RS232 serial communication |
| 1 KNX interface |
|
|
|
|
|
|
|
|
CPU and Data storage
|
| Dual core processor for high-speed regulation and communication |
| 1st processor 100% dedicated for the regulation |
| 2nd processor for communication and data management also used as Web platform |
| 4Gb of flash memory for system information data and logging data |
|
|
Regulation capabilities
|
| Up to 6 Heating circuits |
| 2 Solar loop circuit |
| Up to 4 boilers including Wood stove |
| 1 Swimming pool |
| 1 to 4 boilers |
|
|
|
|
|
|
|
Software
|
|
| Web based firmware application. |
| Internet connectable. |
| Warnings and alarms sent by e-mail on demand from out the device. |
| Off line statistic menu. |
| Real time status request. |
| Easy tune up feature. |
| Powerfull fault analyse. |
| Remote control over the internet by PC, tablets or Smart phones. |
| Smart calendar setup for individual life style. |
| Implemented interface to home automation devices trough the KNX interface. |
| The software offer a high efficient regulation as well as a flexibel and versatile |
| engine providing a solution to various kind hydraulic design. |
|
|
|
|
General Information
|
| Power Supply 230 Vac – 50Hz |
| Dimension : 300 x 200 x 50 mm |
| Weight : 2Kg |
|
| Easy wiring thanks to high quality clips plug terminals |
| Analog input resolution: 14Bits |
| Analog outputs resolution : 8 bits |
|
|
|
|